Studien & Anwenderberichte

Hier finden Sie Studien, Abstracts und Anwenderberichte. Mit diesen Informationen möchten wir Sie in Ihrer Arbeit gerne unterstützen.





Suche nach Studien & Anwenderberichten:
Suche nach Studien & Anwenderberichten
Anzahl: 176
Mehr Info
Bulk-Fill vs. Layered Resin Composite Restorations in Class II Cavities: Six-Month Results
Studie Roland Frankenberger, Meike Schulz, Severin Holl, Thomas Seitner, Matthias J. Roggendorf1
Department of Operative Dentistry and Endodontics, Medical Center for Dentistry, University Medical Center Giessen and Marburg, Campus Marburg, Georg-Voigt-Str. 3, D-35039 Marburg, Germany.
15.05.2012

Summary Objectives: In a controlled prospective split-mouth study, clinical behavior of two different resin composites philosophies (2-mm layering vs. 5-mm bulk fill) in Class II cavities was observed over six months. Methods: Forty-three patients received 118 direct resin composite restorations (OptiBond FL/SonicFILL n=64; OptiBond FL/Herculite XRV: n=54) by three dentists in two private dental offices. Restorations were examined according to modified USPHS criteria at baseline, after three and six months.


 
Mehr Info
Implant Surface Decontamination Methods. A Scanning Electron Microscopic Evaluation.
Studie Rapoport T, Weitz, D, Caton J, Wernisch J, Romanos GE
Division of Periodontics, Eastman Institute for Oral health, University of Rochester, Rochester, NY, USA and Technologic University of Vienna
15.02.2012

Abstract: Background: Several therapies have been proposed to treat periimplant inflammatory conditions by removal of biofilm using various methods from exposed implant surfaces. Objective: The aim of this study was to compare possible alterations in titanium surfaces after the use of different treatment methods. Materials and Methods: 40 titanium (machined and SLA) discs were “cleaned” (mimic scaling of an implant surface) using different methods: Conventional Gracey currette, titanium, plastic curettes, SONICflex device (KaVo), Ultrasonic devices (NSK and Cavitron, Dentsply) with special plastic tips, CO₂laser (2W, Pulsed mode), Er:YAG laser (KaVo, at 100 mJ/pulse and 10 pps) and 980nm diode laser (KaVo, 2w power setting, non- contact mode). The disc surfaces were observed using scanning electron microscopy (SEM).


 
Mehr Info
Effects of different root surface cleaning methods on root morphology. A scanning electron microscopic evaluation.
Studie Weitz D, Rapoport T, Caton J, Wernisch J, Romanos GE
Division of Periodontology, Eastman Institute for Oral Health, Rochester, New York, USA; Technical University of Vienna, Vienna, Austria
14.02.2012

Abstract: Aim: Various methods are available to accomplish the goals of root scaling. The aim of this study was to examine the effects of different root surface cleaning methods on root morphology using scanning electron microscopy. Material and Methods: 14 extracted human teeth were separated into seven groups of two teeth. Each group received 30 seconds of root instrumentation via one of the following: conventional curette (HuFriedy); air scaler (SONICflex, KaVo); ultrasonics A and B (A: Cavitron, Dentsply; B: NSK, Brasseler); Er:YAG laser (KaVo, at 100 mJ/pulse and 10 pps); CO2 laser (DEKA, at 0.5 W and 5 Hertz); and 980nm diode laser (KaVo, at 3 W power, pulse mode). Scanning electron microscopy (SEM) was used to observe morphological changes in root surfaces following instrumentation.


 
Mehr Info
Die richtige Haltung sollte intuitiv eingenommen werden
Anwenderbericht ZA Per Fossdal
Kempten
DZW Die ZahnarztWoche 49/2011, 02.01.2012

Zu jeder Behandlung eines Patienten gibt es eine ganze Reihe von Überlegungen, die zu treffen sind. Untersuchung, Diagnose und Behandlungsplanung, und natürlich auch die Behandlung selbst, werden in aller Regel bewusst und umsichtig durchgeführt. Wenn aber die Therapie an sich beginnt, finden „nebensächliche“ Begleitumstände, wie die Patientenlagerung und die Sitzposition des Zahnarztes oder der Zahnärztin, häufig keine Beachtung.


© 2012 Zahnärztlicher Fach-Verlag GmbH
 
Mehr Info
Relationship between laser fluorescence values and visual evaluation of fissure caries in schoolchildren – a field study
Studie Seppä, L., Anttonen, V., Niinimaa, A. and Hausen, H.
International Journal of Paediatric Dentistry. doi: 10.1111/j.1365-263X.2012.01221.x, 01.01.2012

Background: In our previous study of oral health intervention in children, laser fluorescence (LF) values of occlusal surfaces were reduced after 1 year. Aim: The aim of this study was to explore the relationship between DIAGNOdent pen values and clinical status of the occlusal surfaces. Design: The study conducted in 2007 and 2008 in 700 children aged 13–14 included a clinical examination and LFpen measurement of the occlusal surfaces of first and second molars. Four teams consisting of a dental hygienist and a dental nurse performed the examinations on school premises. The dental hygienist scored the surfaces using the Nyvad criteria for caries assessment; the surfaces were then scanned using a DIAGNOdent pen® device.


© 2012 Wiley
 
Mehr Info
Antinfekční terapie parodontitis
Studie Jamal M. Stein, Priv.-Doz., Dr. med. dent., M.Sc.*, Pia-Merete Jervøe-Storm, Priv.-Doz., Dr. med. dent.**
*Universitätsklinikum der Rheinisch-Westfälischen Technischen Hochschule Aachen; **Rheinische Friedrich-Wilhelms-Universität Bonn
Quintessenz Parodontologie 12. ročník, listopad 2011, 16.12.2011

V posledních letech se stále více v parodontologii etabloval pojem „antiinfekční terapie“ a to jako synonymum pro nechirurgickou terapii parodontitis. Označení „antiinfekční terapie“ podtrhuje myšlenku, že při léčbě parodontitis, která se zaměřuje na její příčinu, se jedná o potírání multibakterielní infekce.


© 2011 Quintessenz Verlag
 
Mehr Info
La mise en oeuvre sonique
Anwenderbericht Dr Marc Lachoviez; Dr. Gérard Aboudharam; Dr. Hervé Tassery; Dr. Stéphane Cazier;
Dentoscope No. 89 - 2011, 16.11.2011

Il s’agit d’une nouvelle génération de composites améliorés pour une mise en oeuvre par le biais d’une activation sonique (6 500 hz). Ce matériau est compatible avec l’ensemble des adhésifs automordançant ou en mordançage total. La mise en oeuvre sonique améliore l’adaptation du composite aux parois des cavités et offre non seulement un confort de travail appréciable, mais aussi une grande rapidité tout en préservant la qualité des obturations.


© 2011 Dentoscope
 
Mehr Info
Risiko Rücken - von Anfang an richtig sitzen
Anwenderbericht Christin Jahn
Leipzig
dentalfresh #3 2011 , 19.10.2011

„Zahnmedizin und Rückenschmerzen gehören zusammen wie Bergbau und Staublunge“, schreibt der User „Sir Kent“ in dem Internetforum Medi-Learn. „Roxi“ berichtet, dass ihm vom Zahnmedizinstudium abgeraten worden sei, da man sich hier den Rücken kaputt mache.


© 2011 Oemus Media AG
 
Mehr Info
Aus Future Concept wird nun ARCTICA
Anwenderbericht Anke Westphal
Biberach
Dentalzeitung 05/2011, 18.10.2011

Konzeptstudien der Automobilindustrie geben einen Ausblick auf zukünftige Fahrzeuge; Future Concepts geben einen Ausblick auf Innovationen, die den Dentalmarkt verändern. In beiden Fällen – bei Automobilherstellern wie bei Dentalunternehmen – werden dann in dieser Reifephase über Monate hinweg Stimmungen und Meinungen gesammelt, die das Projekt beeinflussen.


© 2011 Oemus Media AG
 
Mehr Info
3-D-Röntgen in der Praxis
Anwenderbericht Dr. Sven Schubert
Zwickau
Implantologie Journal 07 2011, 27.09.2011

Mit der Gründung meiner Praxis im Jahre 1994 habe ich mir die Prämisse gesetzt, durch die Investition in innovative Geräte und Behandlungsmethoden für meine Patienten und mich eine Verbesserung der Behandlungsabläufe und somit auch der Behandlungsqualität zu erreichen. Der Schwerpunkt unserer Praxistätigkeit liegt dabei im Erhalt und der vollständigen Wiederherstellung des orofazialen Systems mittels Implantologie, Endo dontie, Laserzahnheilkunde und CAD/CAM-gefertigten Zahnersatz. Zur Erreichung dieser Ziele ist eine optimale Diagnostik unerlässlich.


© 2011 Oemus Media AG
 

Kontakt:
Clinical Affairs

Dr. Emanuel von Kienlin
KaVo Dental GmbH
Bismarckring 39
D-88400 Biberach/Riss
Tel.: +49 7351 56 -3615
Fax: +49 7351 56 -71414
clinicalaffairs@kavo.com


Sprechen Sie uns an:
 
 
 
 
Land*
 
 

Für weitergehende Informationen und produktspezifische Testmöglichkeiten bin ich damit einverstanden, dass sich ein KaVo-Experte bei mir meldet.

* Pflichtfelder
KaVo Dental GmbH
Bismarckring 39
88400 Biberach/Riß
Fon: +49 73 51 / 56-0
Fax: +49 73 51 / 56-14 88